Product supporting products | ||||||||
Inverter | Hybrid Inverter EAHI-5K 5kW(IP65) | |||||||
Solar panels | EN-DHM-72X10-540-555W、EN-DHM-72L9-445-455W、EN-DHM-60L9-370-380W | |||||||
battery | EAST Lithium batt. 48V 100Ah LFP 4.8kWH |
Model | Minimum Order Quantity | USD (minimum) | USD (max) | UNIT |
Hybrid Inverter EAHI-5K 5kW(IP65) | 40 sets (MOQ one pallet) | 1200.00 | 1400 | tower |
EN-DHM-72X10-540-555W | 31 pieces (pcs/pallet, 620pcs/40HQ) | 0.36 | 0.42 | watt |
EN-DHM-72L9-445~455W | 31 pieces (pcs/pallet, 620pcs/40HQ) | 0.36 | 0.42 | watt |
EN-DHM-60L9-370-380W | 31 pieces (pcs/pallet, 620pcs/40HQ) | 0.36 | 0.42 | watt |
EAST Lithium batt. 48V 100Ah LFP 4.8kWH | Matching inverter, no specific quantity requirements | 1498 | 1747 | grain |
MODEL | EAHI-5k | BATTERY | ||
Rate power | 5000W | Battery type | Li-ion, Lead-acid battery | |
Operating mode | Flexible setting via upper computer software or display screen | Rated voltage | 48 Vdc | |
PV INPUT | Voltage range | 42 ~ 58 Vdc | ||
Max. input power | 6500W | Charging current | Max. 100A | |
Max. input voltage | 550 Vdc | AC charge | Support | |
Rated input voltage | 360 Vdc | Max. charge voltage | 58V(Settable) | |
Start-up voltage | 100 Vdc | Max. discharge current | 100A | |
Initial feeding voltage | 150 Vdc | Charging curve | BMS(Lithium battery ) | |
MPPT voltage range | 100 ~ 540 Vdc (220 ~ 450 Vdc) | 3-Stage( Lead-acid battery) | ||
(Full load) | EFFICIENCY | |||
Max. input current | 15A/15A | Max. efficiency | 97.80% | |
Number of MPPTs | 2 | MPPT efficiency | 99.90% | |
AC OUTPUT | Battery charge discharge efficiency | 94.30% | ||
PHASE | Single phase(L+N+PE) | OTHERS | ||
Rated AC power | 5000 VA /5000W | Protections | Over/under voltage, over/under-frequency, over load, short-circuit, over temperature, PV and battery reverse polarity, leakage current, insulation resistance, Anti islanding protection | |
Rated output voltage | 230 Vac | Communications | USB / RS485 (standard), SNMP / Wi-Fi / GPRS (optional) | |
Output voltage range | 184 ~276 Vac | Warning | LED,Buzzer | |
Rated output frequency | 50 / 60 Hz | Display | LED/LCD | |
Output frequency range | 50 ± 5 / 60 ± 5 Hz | Standards | EN 62109-1, IEC62109-2, EN 61000-6-2,EN 61000-6-3, VDE-AR-N 4105, DIN VDE 0126-1-1, DIN VDE V 0124-100, CEI 0-21,G83 | |
Rated output current | 21.8 A | IP rating | IP 65 | |
Power factor | 0.8 (leading) ~ 0.8(lagging) | Operating temperature | -25 ~ 60℃ (> 45℃ derating) | |
THDI(@ Rated Power) | ≤ 3% | Cooling mode | Natural cooling | |
EPS OUTPUT | Installation mode | Wall hanging | ||
Rated EPS power | 5000 VA /5000W | Relative humidity | 0 ~ 90% | |
Rated EPS voltage | 230 Vac (208 / 220 / 240 Vac settable) | Altitude | ≤2000 m (> 2000 m derating) | |
Rated EPS current | 21.8 A | Noise level at 1 m | ≤ 25 dB | |
EPS voltage range | 184 ~ 276 Vac | Topology | Transformer | |
EPS frequency range | 50 / 60 Hz ± 1% | Dimensions (W×H×D) (mm) | 548×440×197mm | |
THDV | ≤ 3% (linear load) | Weight (kg) | 23.4kg | |
Over capacity | 110%,60S/120%,30S/150%,10S | |||
TRANSFER TIME | ≤ 20 ms |
Models | EHB48100R15S | ||
Rated capacity / Ah | 100 | ||
Rated voltage / V | 48 | ||
Operating voltage range / V | 37.5~54.75 | ||
Standard charging current / A | 100 | ||
Maximum charging current / A | 100 | ||
Standard discharging current / A | 25 | ||
Maximum discharging current / A | 100 | ||
Series connection number of standard boxes | 15 | ||
Size (W x D x H) mm | 440 x 400 x 132 | ||
Weight (excluding cabinet) / Kg | 42 | ||
Operating temperature / P | Discharging: - 20 °C ~ 55 °C; Charging: 0 °C ~ 55 °C | ||
Number of cycle / times | 4000 times standard discharging and charging & 100DOD% | ||
Communication method | RS485 / 232 | ||
IP rating | IP40 | ||
Battery type | LFP |